OUTER_SCF
parameters controlling the outer SCF loop [Edit on GitHub]
Keywords
Keyword descriptions
- SECTION_PARAMETERS: logical = F
Lone keyword:
T
Usage: &OUTER_SCF ON
controls the activation of the outer SCF loop [Edit on GitHub]
- BISECT_TRUST_COUNT: integer = 10
Usage: BISECT_TRUST_COUNT 5
Maximum number of times the same point will be used in bisection, a small number guards against the effect of wrongly converged states. [Edit on GitHub]
- DIIS_BUFFER_LENGTH: integer = 3
Usage: DIIS_BUFFER_LENGTH 5
Maximum number of DIIS vectors used [Edit on GitHub]
- EPS_SCF: real = 1.00000000E-005
Usage: EPS_SCF 1.0E-6
Mentions: ⭐Constrained DFT
The target gradient of the outer SCF variables. Notice that the EPS_SCF of the inner loop also determines the value that can be reached in the outer loop, typically EPS_SCF of the outer loop must be smaller than or equal to EPS_SCF of the inner loop. [Edit on GitHub]
- EXTRAPOLATION_ORDER: integer = 3
Usage: EXTRAPOLATION_ORDER 5
Number of past states used in the extrapolation of the variables during e.g. MD [Edit on GitHub]
- MAX_SCF: integer = 50
Usage: MAX_SCF 20
The maximum number of outer loops [Edit on GitHub]
- OPTIMIZER: enum = NONE
Usage: OPTIMIZER SD
Valid values:
SD
Takes steps in the direction of the gradient, multiplied by step_sizeDIIS
Uses a Direct Inversion in the Iterative Subspace methodNONE
Do nothing, useful only with the none typeBISECT
Bisection of the gradient, useful for difficult one dimensional casesBROYDEN
Broyden’s method. Variant defined in BROYDEN_TYPE.NEWTON
Newton’s method. Only compatible with CDFT constraints.SECANT
Secant method. Only for one dimensional cases. See Broyden for multidimensional cases.NEWTON_LS
Newton’s method with backtracking line search to find the optimal step size. Only compatible with CDFT constraints. Starts from the regular Newton solution and successively reduces the step size until the L2 norm of the CDFT gradient decreases or MAX_LS steps is reached. Potentially very expensive because each iteration performs a full SCF calculation.
Mentions: ⭐Constrained DFT
Method used to bring the outer loop to a stationary point [Edit on GitHub]
- STEP_SIZE: real = 5.00000000E-001
Usage: STEP_SIZE -1.0
The initial step_size used in the optimizer (currently steepest descent). Note that in cases where a sadle point is sought for (constrained DFT), this can be negative. For Newton and Broyden optimizers, use a value less/higher than the default 1.0 (in absolute value, the sign is not significant) to active an under/overrelaxed optimizer. [Edit on GitHub]
- TYPE: enum = NONE
Usage: TYPE DDAPC_CONSTRAINT
Valid values:
DDAPC_CONSTRAINT
Enforce a constraint on the DDAPC, requires the corresponding sectionS2_CONSTRAINT
Enforce a constraint on the S2, requires the corresponding sectionBASIS_CENTER_OPT
Optimize positions of basis functions, if atom types FLOATING_BASIS_CENTER are definedCDFT_CONSTRAINT
Enforce a constraint on a generic CDFT weight population. Requires the corresponding section QS&CDFT which determines the type of weight used.NONE
Do nothing in the outer loop, useful for resetting the inner loop,
Specifies which kind of outer SCF should be employed [Edit on GitHub]