Back to the main page of this manual | Input reference of CP2K version 2023.1 |
CP2K_INPUT /
FORCE_EVAL /
MM /
FORCEFIELD /
SPLINE
EMAX_ACCURACY {Real} |
|
Specify the maximum value of energy used to check the accuracy requested through EPS_SPLINE. Energy values larger than EMAX_ACCURACY generally do not satisfy the requested accuracy | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value:
2.00000000E-002 |
|
Default unit:
[hartree]
|
EMAX_SPLINE {Real} |
|
Specify the maximum value of the potential up to which splines will be constructed | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value:
5.00000000E-001 |
|
Default unit:
[hartree]
|
EPS_SPLINE {Real} |
|
Specify the threshold for the choice of the number of points used in the splines (comparing the splined value with the analytically evaluated one) | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value:
1.00000000E-007 |
|
Default unit:
[hartree]
|
NPOINTS {Integer} |
|
Override the default search for an accurate spline by specifying a fixed number of spline points. | |
This keyword cannot be repeated and it expects precisely one integer. | |
Default value:
-1 |
R0_NB {Real} |
|
Specify the minimum value of the distance interval that brackets the value of emax_spline. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value:
4.76259488E-001 |
|
Default unit:
[angstrom]
|
RCUT_NB {Real} |
|
Cutoff radius for nonbonded interactions. This value overrides the value specified in the potential definition and is global for all potentials. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value:
-1.00000000E+000 |
|
Default unit:
[angstrom]
|
UNIQUE_SPLINE {Logical} |
|
For few potentials (Lennard-Jones) one global optimal spline is generated instead of different optimal splines for each kind of potential | |
This keyword cannot be repeated and it expects precisely one logical. | |
The lone keyword behaves as a switch to
.TRUE. |
|
Default value:
.FALSE. |
Back to the main page of this manual or the CP2K home page | (Last update: 31.12.2022) |