Back to the main page of this manual | Input reference of CP2K version 2023.2 |
CP2K_INPUT /
FORCE_EVAL /
MM /
POISSON /
IMPLICIT /
DIRICHLET_BC /
AA_CYLINDRICAL
APX_TYPE {Keyword} |
|
Specifies the type of the n-gonal prism approximating the cylinder. | |
This keyword cannot be repeated and it expects precisely one keyword. | |
Default value:
CIRCUMSCRIBED |
|
List of valid keywords:
|
BASE_CENTER {Real} {Real} |
|
The y and z coordinates (x and z or x and y coordinates, depending on the choice of the parallel axis) of the cylinder's base center. | |
This keyword cannot be repeated and it expects precisely 2 reals. | |
Default unit:
[angstrom]
|
BASE_RADIUS {Real} |
|
The base radius of the cylinder. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value:
1.00000000E+000 |
|
Default unit:
[angstrom]
|
DELTA_ALPHA {Real} |
|
A central angle specifying the gap between the faces of the n-gonal prism. To avoide overlap between the cuboids (of the given thickness) built on top of the faces, a larger value is required if the number of faces (N_SIDES) is quite few and/or the base radius is fairly small. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value:
5.00000000E-002 |
|
Default unit:
[rad]
|
FREQUENCY {Real} |
|
The frequency with which the oscillating fraction oscillates. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value:
0.00000000E+000 |
|
Default unit:
[s^-1]
|
N_PRTN {Integer} {Integer} |
|
The number of partitions along the face edges of the prism for tiling. If the edges have different lengths, from the two given values, the larger one will be assigned to the longer edge. | |
This keyword cannot be repeated and it expects precisely 2 integers. | |
Default values:
1 1 |
N_SIDES {Integer} |
|
The number of sides (faces) of the n-gonal prism approximating the cylinder. | |
This keyword cannot be repeated and it expects precisely one integer. | |
Default value:
5 |
OSCILLATING_FRACTION {Real} |
|
A fraction of the field can be set to oscilate over time. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value:
0.00000000E+000 |
PARALLEL_AXIS {Keyword} |
|
The coordinate axis that the cylindrical region extends along. | |
This keyword cannot be repeated and it expects precisely one keyword. | |
List of valid keywords:
|
PHASE {Real} |
|
The phase of the oscillattion. A phase of zero corresponds to a cosine function. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value:
0.00000000E+000 |
SMOOTHING_WIDTH {Real} |
|
The width of the transition region between the Dirichlet subdomain and its surrounding. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value:
2.00000000E-001 |
|
Default unit:
[angstrom]
|
|
Alias names for this keyword: SIGMA |
THICKNESS {Real} |
|
The thickness of the cylinder. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value:
7.50000000E-001 |
|
Default unit:
[angstrom]
|
V_D {Real} |
|
The value of the fixed potential to be imposed at the cylindrical Dirichlet boundary. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default unit:
[volt]
|
XTNT {Real} {Real} |
|
The extents of the cylinder along its central axis. | |
This keyword cannot be repeated and it expects precisely 2 reals. | |
Default unit:
[angstrom]
|
Back to the main page of this manual or the CP2K home page | (Last update: 22.7.2023) |