| Back to the main page of this manual | Input reference of CP2K version 2.2.426 |
| A {REAL} | |
| Defines the A parameter of the Buckingham potential | |
| This required keyword cannot be repeated and it expects precisely one real. | |
| Default unit: [K_e] |
| ATOMS {KIND1} {KIND2} | |
| Defines the atomic kind involved in the nonbond potential | |
| This required keyword cannot be repeated and it expects precisely 2 words. |
| B {REAL} | |
| Defines the B parameter of the Buckingham potential | |
| This required keyword cannot be repeated and it expects precisely one real. | |
| Default unit: [angstrom^-1] |
| C {REAL} | |
| Defines the C parameter of the Buckingham potential | |
| This required keyword cannot be repeated and it expects precisely one real. | |
| Default unit: [angstrom^6K_e] |
| POLY1 C1 C2 C3 .. | |
| Coefficients of the polynomial used in the second rangeThis keyword can be repeated several times. | |
| This optional keyword can be repeated and it expects a list of reals. | |
| Default unit: [K_e] |
| POLY1 C1 C2 C3 .. | |
| Coefficients of the polynomial used in the third rangeThis keyword can be repeated several times. | |
| This optional keyword can be repeated and it expects a list of reals. | |
| Default unit: [K_e] |
| R1 {REAL} | |
| Defines the upper bound of the first range | |
| This required keyword cannot be repeated and it expects precisely one real. | |
| Default unit: [angstrom] |
| R2 {REAL} | |
| Defines the upper bound of the second range | |
| This required keyword cannot be repeated and it expects precisely one real. | |
| Default unit: [angstrom] |
| R3 {REAL} | |
| Defines the upper bound of the third range | |
| This required keyword cannot be repeated and it expects precisely one real. | |
| Default unit: [angstrom] |
| RCUT {REAL} | |
| Defines the cutoff parameter of the Buckingham potential | |
| This optional keyword cannot be repeated and it expects precisely one real. | |
| Default value: 1.00000000E+01 | |
| Default unit: [angstrom] |
| RMAX {REAL} | |
| Defines the upper bound of the potential. If not set the range is the full range generate by the spline | |
| This required keyword cannot be repeated and it expects precisely one real. | |
| Default unit: [angstrom] |
| RMIN {REAL} | |
| Defines the lower bound of the potential. If not set the range is the full range generate by the spline | |
| This required keyword cannot be repeated and it expects precisely one real. | |
| Default unit: [angstrom] |