Back to the main page of this manual | Input reference of CP2K version 2.2.426 |
INTEGER_TOTAL_CHARGE TRUE | |
Forces the total charge to be integer | |
This optional keyword cannot be repeated and it expects precisely one logical. | |
Default value: .TRUE. |
RESTRAIN_HEAVIES_STRENGTH 0.0001 | |
If defined, enforce the restraint of non-hydrogen atoms to zero. Its value is thestrenght of the restraint on the heavy atoms. | |
This optional keyword cannot be repeated and it expects precisely one real. | |
Default value: 1.00000000E-06 |
RESTRAIN_HEAVIES_TO_ZERO FALSE | |
Restrain non-hydrogen atoms to zero. | |
This optional keyword cannot be repeated and it expects precisely one logical. | |
Default value: .TRUE. |
RMAX 2.5 | |
Specifies the maximum distance a fit point is away from an atom. | |
This optional keyword cannot be repeated and it expects precisely one real. | |
Default value: 2.50000000E+00 | |
Default unit: [angstrom] |
RMIN 2.1 | |
Specifies the minimum distance a fit point is away from an atom. | |
This optional keyword cannot be repeated and it expects precisely one real. | |
Default value: 2.10000000E+00 | |
Default unit: [angstrom] |
STRIDE 2 2 2 | |
The stride (X,Y,Z) used to write the cube file (larger values result in smaller cube files). You can provide 3 numbers (for X,Y,Z) or 1 number valid for all components. | |
This optional keyword cannot be repeated and it expects a list of integers. | |
Default value: 2 2 2 |
X_HI 5. | |
Specifies the upper boundary of the box along X used to sample the potential. | |
This optional keyword cannot be repeated and it expects precisely one real. | |
Default unit: [angstrom] |
X_LOW -15. | |
Specifies the lower boundary of the box along X used to sample the potential. | |
This optional keyword cannot be repeated and it expects precisely one real. | |
Default unit: [angstrom] |
Y_HI 5. | |
Specifies the upper boundary of the box along Y used to sample the potential. | |
This optional keyword cannot be repeated and it expects precisely one real. | |
Default unit: [angstrom] |
Y_LOW -15. | |
Specifies the lower boundary of the box along Y used to sample the potential. | |
This optional keyword cannot be repeated and it expects precisely one real. | |
Default unit: [angstrom] |
Z_HI 5. | |
Specifies the upper boundary of the box along Z used to sample the potential. | |
This optional keyword cannot be repeated and it expects precisely one real. | |
Default unit: [angstrom] |
Z_LOW -15. | |
Specifies the lower boundary of the box along Z used to sample the potential. | |
This optional keyword cannot be repeated and it expects precisely one real. | |
Default unit: [angstrom] |