| Back to the main page of this manual | Input reference of CP2K version 2.4.0 (Revision 12993) |
| DX <REAL> | |
| Parameter used for computing the derivative with the Ridders method. | |
| This optional keyword cannot be repeated and it expects precisely one real. | |
| Default value: 1.00000000E-01 | |
| Default unit: [bohr] |
| ERROR_LIMIT <REAL> | |
| Checks that the error in computing the derivative is not larger than the value set. In case prints a warning message. | |
| This optional keyword cannot be repeated and it expects precisely one real. | |
| Default value: 1.00000000E-12 |
| FUNCTION X^2+Y^2+Z^2+LOG(ABS(X+Y)) | |
| Specifies the functional form in mathematical notation. Variables must be the atomic coordinates (X,Y,Z) of the grid. | |
| This required keyword cannot be repeated and it expects precisely one string. |
| PARAMETERS A B D | |
| Defines the parameters of the functional form | |
| This required keyword can be repeated and it expects a list of words. |
| STATIC T | |
| Specifies the external potential as STATIC or time dependent. At the moment only static potentials are implemented. | |
| This optional keyword cannot be repeated and it expects precisely one logical. | |
| The lone keyword behaves as a switch to .TRUE. | |
| Default value: .TRUE. |
| UNITS ANGSTROM EV*ANGSTROM^-1 ANGSTROM^1 K | |
| Optionally, allows to define valid CP2K unit strings for each parameter value. It is assumed that the corresponding parameter value is specified in this unit. | |
| This optional keyword can be repeated and it expects a list of words. |
| VALUES | |
| Defines the values of parameter of the functional form | |
| This required keyword can be repeated and it expects a list of reals. | |
| Default unit: [internal_cp2k] |
| Back to the main page of this manual or the CP2K home page | (Last update: 19.6.2013) |