| Back to the main page of this manual | Input reference of CP2K version 2.4.0 (Revision 12993) |
| RMAX 2.5 | |
| Specifies the maximum distance a fit point is away from an atom. Valid for all atomic kinds for which no RMAX_KIND are specified. | |
| This optional keyword cannot be repeated and it expects precisely one real. | |
| Default value: 2.50000000E+00 | |
| Default unit: [angstrom] |
| RMAX 2.5 BR | |
| Specifies the maximum distance a fit point is away from an atom of a given kind | |
| This optional keyword can be repeated and it expects a list of words. |
| RMIN 2.1 | |
| Specifies the minimum distance a fit point is away from an atom. Valid for all atomic kinds for which no RMIN_KIND are specified. | |
| This optional keyword cannot be repeated and it expects precisely one real. | |
| Default value: 2.10000000E+00 | |
| Default unit: [angstrom] |
| RMIN 2.1 BR | |
| Specifies the minimum distance a fit point is away from an atom of a given kind | |
| This optional keyword can be repeated and it expects a list of words. |
| X_HI 5. | |
| Specifies the upper boundary of the box along X used to sample the potential. | |
| This optional keyword cannot be repeated and it expects precisely one real. | |
| Default unit: [angstrom] |
| X_LOW -15. | |
| Specifies the lower boundary of the box along X used to sample the potential. | |
| This optional keyword cannot be repeated and it expects precisely one real. | |
| Default unit: [angstrom] |
| Y_HI 5. | |
| Specifies the upper boundary of the box along Y used to sample the potential. | |
| This optional keyword cannot be repeated and it expects precisely one real. | |
| Default unit: [angstrom] |
| Y_LOW -15. | |
| Specifies the lower boundary of the box along Y used to sample the potential. | |
| This optional keyword cannot be repeated and it expects precisely one real. | |
| Default unit: [angstrom] |
| Z_HI 5. | |
| Specifies the upper boundary of the box along Z used to sample the potential. | |
| This optional keyword cannot be repeated and it expects precisely one real. | |
| Default unit: [angstrom] |
| Z_LOW -15. | |
| Specifies the lower boundary of the box along Z used to sample the potential. | |
| This optional keyword cannot be repeated and it expects precisely one real. | |
| Default unit: [angstrom] |
| Back to the main page of this manual or the CP2K home page | (Last update: 19.6.2013) |