Back to the main page of this manual | Input reference of CP2K version 2.4.0 (Revision 12993) |
PRESSURE REAL | |
Initial pressure | |
This optional keyword cannot be repeated and it expects precisely one real. | |
Default value: 0.00000000E+00 | |
Default unit: [bar] |
TEMPERATURE REAL | |
Barostat initial temperature. If not set, the ensemble temperature is used instead. | |
This optional keyword cannot be repeated and it expects precisely one real. | |
Default unit: [K] |
TEMP_TOL REAL | |
Maximum oscillation of the Barostat temperature imposed by recaling. | |
This optional keyword cannot be repeated and it expects precisely one real. | |
Default value: 0.00000000E+00 | |
Default unit: [K] |
TIMECON REAL | |
Barostat time constant | |
This optional keyword cannot be repeated and it expects precisely one real. | |
Default value: 1.00000000E+03 | |
Default unit: [fs] |
VIRIAL (XYZ | X | Y | Z | XY| XZ | YZ) | |
For NPT_F only: allows the screening of one or more components of the virial in order to relax the cell only along specific cartesian axis | |
This optional keyword cannot be repeated and it expects precisely one keyword. | |
Default value: XYZ | |
List of valid keywords:
|
Back to the main page of this manual or the CP2K home page | (Last update: 19.6.2013) |