| Back to the main page of this manual | Input reference of CP2K version 4.1 (Revision svn:17462) |
| BASE_CENTER {Real} {Real} | |
| The y and z coordinates of the annulus' base center. | |
| This keyword cannot be repeated and it expects precisely 2 reals. | |
| Default unit: [angstrom] |
| BASE_RADII {Real} {Real} | |
| The base radius of the annulus. | |
| This keyword cannot be repeated and it expects precisely 2 reals. | |
| Default unit: [angstrom] |
| DIELECTRIC_CONSTANT {Real} | |
| value of the dielectric constant inside the region. | |
| This keyword cannot be repeated and it expects precisely one real. | |
| Default value: 8.00000000E+001 | |
| Alias names for this keyword: EPSILON |
| SMOOTHING_WIDTH {Real} | |
| The width of the standard mollifier. | |
| This keyword cannot be repeated and it expects precisely one real. | |
| Default value: 1.05835442E-001 | |
| Default unit: [angstrom] | |
| Alias names for this keyword: ZETA |
| X_XTNT {Real} {Real} | |
| The X extents of the annulus. | |
| This keyword cannot be repeated and it expects precisely 2 reals. | |
| Default unit: [angstrom] |
| Back to the main page of this manual or the CP2K home page | (Last update: 5.10.2016) |