Back to the main page of this manual | Input reference of CP2K version 4.1 (Revision svn:17462) |
CUTOFF {Real} | |
The cutoff of the finest grid level in the MP2 gpw integration. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value: 3.00000000E+002 |
EPS_FILTER {Real} | |
Determines a threshold for the DBCSR based multiply (usually 10 times smaller than EPS_GRID).Normally, this EPS_FILTER determines accuracy and timing of cubic-scaling RPA calculation. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value: 1.00000000E-009 |
EPS_GRID {Real} | |
Determines a threshold for the GPW based integration | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value: 1.00000000E-008 |
EPS_PGF_ORB_S {Real} | |
Screening for overlap matrix in RI. Usually, it is best to choose this parameter to be very small since the inversion of overlap matrix might be ill-conditioned. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value: 1.00000000E-010 |
MULTIPOLE_TWO_CENT_INT {Logical} | |
Use fast algorithm to calculate two-center RI integrals based on multipole expansion | |
This keyword cannot be repeated and it expects precisely one logical. | |
The lone keyword behaves as a switch to .TRUE. | |
Default value: .FALSE. |
OBARA_SAIKA_OVERLAP {Logical} | |
Use Obara-Saika integrals for two- and three-center integrals. | |
This keyword cannot be repeated and it expects precisely one logical. | |
The lone keyword behaves as a switch to .TRUE. | |
Default value: .FALSE. | |
Alias names for this keyword: OSO |
PRINT_LEVEL {Keyword} | |
How much output is written by the individual groups. | |
This keyword cannot be repeated and it expects precisely one keyword. | |
Default value: SILENT | |
List of valid keywords:
|
|
Alias names for this keyword: IOLEVEL |
REL_CUTOFF {Real} | |
Determines the grid at which a Gaussian is mapped. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value: 5.00000000E+001 | |
Alias names for this keyword: RELATIVE_CUTOFF |
Back to the main page of this manual or the CP2K home page | (Last update: 5.10.2016) |