| Back to the main page of this manual | Input reference of CP2K version 4.1 (Revision svn:17462) |
| ALPHA {Real} | |
| Specifies the scaling factor that defines the movement along the defined direction | |
| This keyword cannot be repeated and it expects precisely one real. |
| ATOM_INDEX_1 {Integer} | |
| Specifies the index of the first atom defining the direction along which the atom will be added | |
| This keyword cannot be repeated and it expects precisely one integer. | |
| Alias names for this keyword: MM1 |
| ATOM_INDEX_2 {Integer} | |
| Specifies the index of the second atom defining the direction along which the atom will be added | |
| This keyword cannot be repeated and it expects precisely one integer. | |
| Alias names for this keyword: MM2 |
| CHARGE {Real} | |
| Specifies the charge for the added source of QM/MM potential | |
| This keyword cannot be repeated and it expects precisely one real. | |
| Default value: 0.00000000E+000 |
| CORR_RADIUS {Real} | |
| Specifies the correction radius used for the QM/MM electrostatic coupling for the added source | |
| This keyword cannot be repeated and it expects precisely one real. | |
| Default value: 8.00000000E-001 | |
| Default unit: [angstrom] |
| RADIUS {Real} | |
| Specifies the radius used for the QM/MM electrostatic coupling for the added source | |
| This keyword cannot be repeated and it expects precisely one real. | |
| Default value: 8.00000000E-001 | |
| Default unit: [angstrom] |
| Back to the main page of this manual or the CP2K home page | (Last update: 5.10.2016) |