| Back to the main page of this manual | Input reference of CP2K version 4.1 (Revision svn:17462) |
| LENGTH {Integer} | |
| length of the Nose-Hoover chain | |
| This keyword cannot be repeated and it expects precisely one integer. | |
| Default value: 3 |
| MTS {Integer} | |
| number of multiple timesteps to be used for the NoseHoover chain | |
| This keyword cannot be repeated and it expects precisely one integer. | |
| Default value: 2 | |
| Alias names for this keyword: MULTIPLE_TIME_STEPS, MULT_T_STEPS |
| TIMECON {Real} | |
| timeconstant of the thermostat chain | |
| This keyword cannot be repeated and it expects precisely one real. | |
| Default value: 1.00000000E+003 | |
| Default unit: [fs] |
| YOSHIDA {Integer} | |
| order of the yoshida integretor used for the thermostat | |
| This keyword cannot be repeated and it expects precisely one integer. | |
| Default value: 3 |
| Back to the main page of this manual or the CP2K home page | (Last update: 5.10.2016) |