Back to the main page of this manual | Input reference of CP2K version 5.1 (Revision svn:18091) |
BOUNDARY_CONDITIONS {Keyword} | |
Specifies the type of boundary conditions. Dirichlet=fixed value, Neumann=zero normal deriv. Mixed and Neumann boundaries essentially requires FFTW3 so that all grid sizes are FFT-able. | |
This keyword cannot be repeated and it expects precisely one keyword. | |
Default value: PERIODIC | |
List of valid keywords:
|
MAX_ITER {Integer} | |
Maximum number of iterations. | |
This keyword cannot be repeated and it expects precisely one integer. | |
Default value: 30 |
NEUMANN_DIRECTIONS {Keyword} | |
Directions in which homogeneous Neumann conditions are imposed. In the remaining directions periodic conditions will be enforced. Having specified MIXED or NEUMANN as BOUNDARY_CONDITIONS, the keyword is meant to be used to combine periodic and homogeneous Neumann conditions at the boundaries of the simulation cell. | |
This keyword cannot be repeated and it expects precisely one keyword. | |
Default value: XYZ | |
List of valid keywords:
|
OR_PARAMETER {Real} | |
Over-relaxation parameter (large epsilon requires smaller omega ~0.1). | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value: 1.00000000E+000 | |
Alias names for this keyword: OMEGA |
TOL {Real} | |
Stopping tolerance. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value: 1.00000000E-008 |
ZERO_INITIAL_GUESS {Logical} | |
Whether or not to use zero potential as initial guess. | |
This keyword cannot be repeated and it expects precisely one logical. | |
The lone keyword behaves as a switch to .TRUE. | |
Default value: .FALSE. |