Back to the main page of this manual | Input reference of CP2K version 5.1 (Revision svn:18091) |
ANGLE_TOLERANCE {Real} | |
This keyword sets the value of the tolerance angle for the line search performed to optimize the orientation of the dimer. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value: 8.72664626E-002 | |
Default unit: [rad] |
DR {Real} | |
This keyword sets the value for the DR parameter. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value: 1.00000000E-002 | |
Default unit: [angstrom] |
INTERPOLATE_GRADIENT {Logical} | |
This keyword controls the interpolation of the gradient whenever possible during the optimization of the Dimer. The use of this keywords saves 1 evaluation of energy/forces. | |
This keyword cannot be repeated and it expects precisely one logical. | |
The lone keyword behaves as a switch to .TRUE. | |
Default value: .TRUE. |
Back to the main page of this manual or the CP2K home page | (Last update: 24.10.2017) |