Back to the main page of this manual | Input reference of CP2K version 5.1 (Revision svn:18091) |
ALPHA_1 {Real} | |
Factor used to decrease acceptance energy, when minima was accepted, should be smaller than 1. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value: 9.80000000E-001 |
ALPHA_2 {Real} | |
Factor used to increase acceptance energy, when minima was rejected, should be larger than 1. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value: 1.02040816E+000 |
BETA_1 {Real} | |
Factor used to increase temperature when escape failed, should be larger than 1. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value: 1.10000000E+000 |
BETA_2 {Real} | |
Factor used to increase temperature when escape found known minima, should be larger than 1. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value: 1.10000000E+000 |
BETA_3 {Real} | |
Factor used to decrease temperature when escape succeeded, should be smaller than 1. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value: 9.09090909E-001 |
E_ACCEPT_INIT {Real} | |
Initial value of acceptance energy | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value: 5.00000000E-003 | |
Default unit: [hartree] |
SHARE_HISTORY {Logical} | |
If set all worker will use a single share history of visited minima. | |
This keyword cannot be repeated and it expects precisely one logical. | |
The lone keyword behaves as a switch to .TRUE. | |
Default value: .FALSE. |
TEMPERATURE_INIT {Real} | |
Initially temperature in Kelvin | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value: 1.00000000E+002 |
Back to the main page of this manual or the CP2K home page | (Last update: 24.10.2017) |