Back to the main page of this manual | Input reference of CP2K version 6.1 (Revision svn:18464) |
A {Real} | |
Defines the A parameter of the dispersion-damped Fumi-Tosi Potential | |
This keyword cannot be repeated and it expects precisely one real. | |
Default unit: [hartree] |
ATOMS {Word} {Word} | |
Defines the atomic kind involved in the BMHFTD nonbond potential | |
This keyword cannot be repeated and it expects precisely 2 words. |
B {Real} | |
Defines the B parameter of the dispersion-damped Fumi-Tosi Potential | |
This keyword cannot be repeated and it expects precisely one real. | |
Default unit: [angstrom^-1] |
BD {Real} | |
Defines the BD parameter of the dispersion-damped Fumi-Tosi Potential | |
This keyword cannot be repeated and it expects precisely one real. | |
Default unit: [angstrom^-1] |
C {Real} | |
Defines the C parameter of the dispersion-damped Fumi-Tosi Potential | |
This keyword cannot be repeated and it expects precisely one real. | |
Default unit: [angstrom^6*hartree] |
D {Real} | |
Defines the D parameter of the dispersion-damped Fumi-Tosi Potential | |
This keyword cannot be repeated and it expects precisely one real. | |
Default unit: [angstrom^8*hartree] |
MAP_ATOMS {Word} {Word} | |
Defines the kinds for which internally is defined the BMHFTD nonbond potential at the moment no species included. | |
This keyword cannot be repeated and it expects precisely 2 words. |
ORDER {Integer} | |
Defines the order for this damping. | |
This keyword cannot be repeated and it expects precisely one integer. | |
Default value: 3 |
RCUT {Real} | |
Defines the cutoff parameter of the BMHFTD potential | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value: 4.12758223E+000 | |
Default unit: [angstrom] |
RMAX {Real} | |
Defines the upper bound of the potential. If not set the range is the full range generate by the spline | |
This keyword cannot be repeated and it expects precisely one real. | |
Default unit: [angstrom] |
RMIN {Real} | |
Defines the lower bound of the potential. If not set the range is the full range generate by the spline | |
This keyword cannot be repeated and it expects precisely one real. | |
Default unit: [angstrom] |
Back to the main page of this manual or the CP2K home page | (Last update: 12.6.2018) |