| Back to the main page of this manual | Input reference of CP2K version 6.1 (Revision svn:18464) | 
| BOUNDARY_CONDITIONS {Keyword} | |
| Specifies the type of boundary conditions. Dirichlet=fixed value, Neumann=zero normal deriv. Mixed and Neumann boundaries essentially requires FFTW3 so that all grid sizes are FFT-able. | |
| This keyword cannot be repeated and it expects precisely one keyword. | |
| Default value: PERIODIC | |
| List of valid keywords: 
 | 
| MAX_ITER {Integer} | |
| Maximum number of iterations. | |
| This keyword cannot be repeated and it expects precisely one integer. | |
| Default value: 30 | 
| NEUMANN_DIRECTIONS {Keyword} | |
| Directions in which homogeneous Neumann conditions are imposed. In the remaining directions periodic conditions will be enforced. Having specified MIXED or NEUMANN as BOUNDARY_CONDITIONS, the keyword is meant to be used to combine periodic and homogeneous Neumann conditions at the boundaries of the simulation cell. | |
| This keyword cannot be repeated and it expects precisely one keyword. | |
| Default value: XYZ | |
| List of valid keywords: 
 | 
| OR_PARAMETER {Real} | |
| Over-relaxation parameter (large epsilon requires smaller omega ~0.1). | |
| This keyword cannot be repeated and it expects precisely one real. | |
| Default value: 1.00000000E+000 | |
| Alias names for this keyword: OMEGA | 
| TOL {Real} | |
| Stopping tolerance. | |
| This keyword cannot be repeated and it expects precisely one real. | |
| Default value: 1.00000000E-008 | 
| ZERO_INITIAL_GUESS {Logical} | |
| Whether or not to use zero potential as initial guess. | |
| This keyword cannot be repeated and it expects precisely one logical. | |
| The lone keyword behaves as a switch to .TRUE. | |
| Default value: .FALSE. | 
| Back to the main page of this manual or the CP2K home page | (Last update: 12.6.2018) |