Back to the main page of this manual | Input reference of CP2K version 9.1 |
CP2K_INPUT /
MOTION /
MD /
ADIABATIC_DYNAMICS /
THERMOSTAT_FAST /
NOSE
LENGTH {Integer} |
|
length of the Nose-Hoover chain | |
This keyword cannot be repeated and it expects precisely one integer. | |
Default value:
3 |
MTS {Integer} |
|
number of multiple timesteps to be used for the NoseHoover chain | |
This keyword cannot be repeated and it expects precisely one integer. | |
Default value:
2 |
|
Alias names for this keyword: MULTIPLE_TIME_STEPS, MULT_T_STEPS |
TIMECON {Real} |
|
timeconstant of the thermostat chain | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value:
1.00000000E+003 |
|
Default unit:
[fs]
|
YOSHIDA {Integer} |
|
order of the yoshida integrator used for the thermostat | |
This keyword cannot be repeated and it expects precisely one integer. | |
Default value:
3 |
Back to the main page of this manual or the CP2K home page | (Last update: 31.12.2021) |