Back to the main page of this manual | Input reference of CP2K version 2022.1 |
CP2K_INPUT /
VIBRATIONAL_ANALYSIS
DX {Real} |
|
Specify the increment to be used to construct the HESSIAN with finite difference method | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value:
1.00000000E-002 |
|
Default unit:
[bohr]
|
FULLY_PERIODIC {Logical} |
|
Avoids to clean rotations from the Hessian matrix. | |
This keyword cannot be repeated and it expects precisely one logical. | |
The lone keyword behaves as a switch to
.TRUE. |
|
Default value:
.FALSE. |
INTENSITIES {Logical} |
|
Calculation of the IR-Intensities. Calculation of dipoles has to be specified explicitly | |
This keyword cannot be repeated and it expects precisely one logical. | |
The lone keyword behaves as a switch to
.TRUE. |
|
Default value:
.FALSE. |
NAMD_PRINT {Logical} |
|
Adjust cartesian eigenvalues / vectors to NewtonX format. | |
This keyword cannot be repeated and it expects precisely one logical. | |
The lone keyword behaves as a switch to
.TRUE. |
|
Default value:
.FALSE. |
NPROC_REP {Integer} |
|
Specify the number of processors to be used per replica environment (for parallel runs). In case of mode selective calculations more than one replica will start a block Davidson algorithm to track more than only one frequency | |
This keyword cannot be repeated and it expects precisely one integer. | |
Default value:
1 |
PROC_DIST_TYPE {Keyword} |
|
Specify the topology of the mapping of processors into replicas. | |
This keyword cannot be repeated and it expects precisely one keyword. | |
Default value:
BLOCKED |
|
List of valid keywords:
|
TC_PRESSURE {Real} |
|
Pressure for the calculation of the thermochemical data | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value:
1.01325000E+005 |
|
Default unit:
[Pa]
|
TC_TEMPERATURE {Real} |
|
Temperature for the calculation of the thermochemical data | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value:
2.73150000E+002 |
|
Default unit:
[K]
|
THERMOCHEMISTRY {Logical} |
|
Calculation of the thermochemical data. Valid for molecules in the gas phase. | |
This keyword cannot be repeated and it expects precisely one logical. | |
The lone keyword behaves as a switch to
.TRUE. |
|
Default value:
.FALSE. |
Back to the main page of this manual or the CP2K home page | (Last update: 8.8.2022) |