GCUT {REAL} | |
Cutoff for charge fit in G-space. | |
This optional keyword cannot be repeated and it expects precisely one real. | |
Default value: 2.44948974E+00 |
MIN_RADIUS {REAL} | |
Specifies the smallest radius of the gaussian used in the fit. All other radius are obtained with the progression factor. | |
This optional keyword cannot be repeated and it expects precisely one real. | |
Default value: 2.64588604E-01 | |
Default unit: [angstrom] |
NUM_GAUSS {INTEGER} | |
Specifies the numbers of gaussian used to fit the QM density for each atomic site. | |
This optional keyword cannot be repeated and it expects precisely one integer. | |
Default value: 3 |
PFACTOR {REAL} | |
Specifies the progression factor for the gaussian exponent for each atomic site. | |
This optional keyword cannot be repeated and it expects precisely one real. | |
Default value: 1.50000000E+00 |
RADII {REAL} {REAL} .. {REAL} | |
Specifies all the radius of the gaussian used in the fit for each atomic site. The use of this keyword disables all other keywords of this section. | |
This optional keyword cannot be repeated and it expects a list of reals. | |
Default unit: [angstrom] |