Back to the main page of this manual | Input reference of CP2K version 2.5.1 (Revision svn:13632) |
&CURRENT {Logical} | |
controls the activation of the induced current calculation | |
This keyword cannot be repeated and it expects precisely one logical. | |
The lone keyword behaves as a switch to .TRUE. | |
Default value: .FALSE. |
CHI_PBC {Logical} | |
Calculate the succeptibility correction to the shift with PBC | |
This keyword cannot be repeated and it expects precisely one logical. | |
The lone keyword behaves as a switch to .TRUE. | |
Default value: .FALSE. |
COMMON_CENTER {Real} {Real} {Real} | |
The common center | |
This keyword cannot be repeated and it expects precisely 3 reals. | |
Default values: 0.00000000E+00 0.00000000E+00 0.00000000E+00 | |
Default unit: [angstrom] |
GAUGE {Keyword} | |
The gauge used to compute the induced current within GAPW. | |
This keyword cannot be repeated and it expects precisely one keyword. | |
Default value: R_AND_STEP_FUNCTION | |
List of valid keywords:
|
GAUGE_ATOM_RADIUS {Real} | |
Build the gauge=atom using only the atoms within this radius. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value: 4.00000000E+00 | |
Default unit: [angstrom] |
NBOX {Integer} {Integer} {Integer} | |
How many boxes along each directions | |
This keyword cannot be repeated and it expects precisely 3 integers. | |
Default values: 4 4 4 |
ORBITAL_CENTER {Keyword} | |
The orbital center. | |
This keyword cannot be repeated and it expects precisely one keyword. | |
Default value: WANNIER | |
List of valid keywords:
|
RESTART_CURRENT {Logical} | |
Restart the induced current density calculation from a previous run (not working yet). | |
This keyword cannot be repeated and it expects precisely one logical. | |
The lone keyword behaves as a switch to .TRUE. | |
Default value: .FALSE. |
SELECTED_STATES_ATOM_RADIUS {Real} | |
Select all the states included in the given radius arround each atoms in SELECTED_STATES_ON_ATOM_LIST. | |
This keyword cannot be repeated and it expects precisely one real. | |
Default value: 4.00000000E+00 | |
Default unit: [angstrom] |
SELECTED_STATES_ON_ATOM_LIST {Integer} ... or a range {Integer}..{Integer} | |
Indexes of the atoms for selecting the states to be used for the response calculations. | |
This keyword can be repeated and it expects a list of integers. |
USE_OLD_GAUGE_ATOM {Logical} | |
Use the old way to compute the gauge. | |
This keyword cannot be repeated and it expects precisely one logical. | |
The lone keyword behaves as a switch to .TRUE. | |
Default value: .TRUE. |